Yellow Dog Enterprise Linux
TOPIC: Connecting to the Blade via Serial-Over-LAN (SOL)
- Log into the Advanced Management Module (AMM) by opening a web browser and navigating to the IP address of the AMM.
- Log in by entering the username and password. If not changed, the default username is USERID and default password is PASSW0RD. Note that 0 is the
number zero, not the letter O.
- From the left-hand panel click "Power/Restart" under "Blade Tasks."
- From the right-hand window select the check box next to the QS2x you wish to restart. Below that, click "Power On."
- Open a terminal Window and type:
telnet {IP address or FQDN of Management Module }” [ENTER]
- Enter your username and password
- You should now have a “system>” prompt
- Type:
console -T system:blade[X]
Where “X” is the number of the slot of the blade you want to connect to, if a blade occupies more then one slot use the slot with the lowest number.
- Reboot the blade via the AMM. Repeatedly press "s" as the blade is powering on; this prevents the QS2x from performing a net boot.
This HOWTO was prepared by Owen Stampflee and Aaron Johnson, Fixstars Solutions, Inc.
|